Rheological
properties |
C |
Melt volume-flow rate |
300 °C; 1.2 kg |
cm³/(10 min) |
ISO 1133 |
9.5 |
C |
Molding shrinkage,
parallel |
60x60x2; 300 °C / MT 80
°C; 500 bar |
% |
ISO 294-4 |
0.65 |
C |
Molding shrinkage,
normal |
60x60x2; 300 °C / MT 80
°C; 500 bar |
% |
ISO 294-4 |
0.7 |
|
Molding shrinkage,
parallel/normal |
Value range based on
general practical experience |
% |
acc. ISO 2577 |
0.6 - 0.8 |
|
Melt mass-flow rate |
300 °C; 1.2 kg |
g/(10 min) |
ISO 1133 |
10 |
Mechanical
properties (23 °C/50 % r. h.) |
C |
Tensile modulus |
1 mm/min |
MPa |
ISO 527-1,-2 |
2400 |
C |
Yield stress |
50 mm/min |
MPa |
ISO 527-1,-2 |
66 |
C |
Yield strain |
50 mm/min |
% |
ISO 527-1,-2 |
6.1 |
C |
Nominal strain at
break |
50 mm/min |
% |
ISO 527-1,-2 |
> 50 |
|
Stress at break |
50 mm/min |
MPa |
ISO 527-1,-2 |
65 |
|
Strain at break |
50 mm/min |
% |
acc. ISO 527-1,-2 |
115 |
C |
Tensile creep modulus |
1 h |
MPa |
ISO 899-1 |
2200 |
C |
Tensile creep modulus |
1000 h |
MPa |
ISO 899-1 |
1900 |
|
Flexural modulus |
2 mm/min |
MPa |
ISO 178 |
2350 |
|
Flexural strength |
2 mm/min |
MPa |
ISO 178 |
98 |
|
Flexural strain at
flexural strength |
2 mm/min |
% |
ISO 178 |
7.0 |
|
Flexural stress at 3.5 %
strain |
2 mm/min |
MPa |
ISO 178 |
74 |
C |
Charpy impact strength |
23 °C |
kJ/m² |
ISO 179-1eU |
N |
C |
Charpy impact strength |
-30 °C |
kJ/m² |
ISO 179-1eU |
N |
|
Charpy notched impact
strength |
23 °C; 3 mm |
kJ/m² |
acc. ISO 179-1eA |
70P |
|
Charpy notched impact
strength |
-30 °C; 3 mm |
kJ/m² |
acc. ISO 179-1eA |
12C |
|
Izod notched impact
strength |
23 °C; 3.2 mm |
kJ/m² |
acc. ISO 180-A |
85P |
|
Izod notched impact
strength |
-30 °C; 3.2 mm |
kJ/m² |
acc. ISO 180-A |
12C |
C |
Puncture maximum force |
23 °C |
N |
ISO 6603-2 |
5400 |
C |
Puncture maximum force |
-30 °C |
N |
ISO 6603-2 |
6300 |
C |
Puncture energy |
23 °C |
J |
ISO 6603-2 |
60 |
C |
Puncture energy |
-30 °C |
J |
ISO 6603-2 |
65 |
|
Ball indentation
hardness |
|
N/mm² |
ISO 2039-1 |
115 |
Thermal
properties |
C |
Glass transition
temperature |
10 °C/min |
°C |
ISO 11357-1,-2 |
145 |
C |
Temperature of deflection
under load |
1.80 MPa |
°C |
ISO 75-1,-2 |
125 |
C |
Temperature of deflection
under load |
0.45 MPa |
°C |
ISO 75-1,-2 |
138 |
C |
Vicat softening
temperature |
50 N; 50 °C/h |
°C |
ISO 306 |
145 |
|
Vicat softening
temperature |
50 N; 120 °C/h |
°C |
ISO 306 |
146 |
C |
Coefficient of linear
thermal expansion, parallel |
23 to 55 °C |
10-4/K |
ISO 11359-1,-2 |
0.65 |
C |
Coefficient of linear
thermal expansion, transverse |
23 to 55 °C |
10-4/K |
ISO 11359-1,-2 |
0.65 |
C |
Burning behavior UL 94
(1.6 mm) [UL
recognition] |
1.5 mm |
Class |
UL 94 |
V-2 |
C |
Burning behavior UL
94 [UL recognition] |
2.4 mm |
Class |
UL 94 |
V-2 |
|
Burning behavior UL
94 [UL recognition] |
0.75 mm |
Class |
UL 94 |
V-2 |
|
Burning behavior UL
94 [UL recognition] |
2.5 mm |
Class |
UL 94 |
HB |
|
Burning behavior UL
94 [UL recognition] |
3.0 mm |
Class |
UL 94 |
HB |
|
Burning behavior UL
94 [UL recognition] |
6.0 mm |
Class |
UL 94 |
HB |
C |
Oxygen index |
Method A |
% |
ISO 4589-2 |
27 |
|
Thermal conductivity |
23 °C |
W/(m·K) |
ISO 8302 |
0.20 |
|
Resistance to heat (ball
pressure test) |
|
°C |
IEC 60695-10-2 |
135 |
|
Temperature index
(Tensile strength) |
20000 h; 1.5 mm |
°C |
IEC 60216-1 |
130 |
|
Halving interval (Tensile
strength) |
1.5 mm |
°C |
IEC 60216-1 |
8.7 |
|
Temperature index
(Tensile impact strength) |
20000 h; 1.5 mm |
°C |
IEC 60216-1 |
120 |
|
Halving interval (Tensile
impact strength) |
1.5 mm |
°C |
IEC 60216-1 |
7.4 |
|
Temperature index
(Electric strength) |
20000 h; 1.5 mm |
°C |
IEC 60216-1 |
135 |
|
Halving interval
(Electric strength) |
1.5 mm |
°C |
IEC 60216-1 |
7.4 |
|
Relative temperature
index (Tensile strength) [UL
recognition] |
1.5 mm |
°C |
UL 746B |
125 |
|
Relative temperature
index (Tensile impact strength)
[UL recognition] |
1.5 mm |
°C |
UL 746B |
115 |
|
Relative temperature
index (Electric strength) [UL
recognition] |
1.5 mm |
°C |
UL 746B |
125 |
|
Glow wire test (GWFI) |
1.0 mm |
°C |
IEC 60695-2-12 |
850 |
|
Glow wire test (GWFI) |
1.5 mm |
°C |
IEC 60695-2-12 |
850 |
|
Glow wire test (GWFI) |
2.0 mm |
°C |
IEC 60695-2-12 |
850 |
|
Glow wire test (GWFI) |
3.0 mm |
°C |
IEC 60695-2-12 |
900 |
|
Glow wire test |
1.5 mm |
°C |
acc. EDF HN60 E.02 |
750 |
|
Glow wire test |
3.0 mm |
°C |
acc. EDF HN60 E.02 |
750 |
|
Application of flame from
small burner |
Method K and F; 2.0 mm |
Class |
DIN 53438-1,-3 |
K1, F1 |
|
Needle flame test |
Method K; 1.5 mm |
s |
IEC 60695-2-2 |
5 |
|
Needle flame test |
Method K; 2.0 mm |
s |
IEC 60695-2-2 |
5 |
|
Needle flame test |
Method K; 3.0 mm |
s |
IEC 60695-2-2 |
10 |
|
Needle flame test |
Method F; 1.5 mm |
s |
IEC 60695-2-2 |
60 |
|
Needle flame test |
Method F; 2.0 mm |
s |
IEC 60695-2-2 |
60 |
|
Needle flame test |
Method F; 3.0 mm |
s |
IEC 60695-2-2 |
120 |
|
Incandescent bar test |
|
Rating |
IEC 60707-BH |
BH2/< 30 mm |
|
Burning rate
(US-FMVSS) |
>=1.0 mm |
mm/min |
ISO 3795 |
passed |
|
Flash ignition
temperature |
Procedure B |
°C |
ASTM D1929 |
470 |
|
Self ignition
temperature |
Procedure B |
°C |
ASTM D1929 |
540 |
Electrical
properties (23 °C/50 % r. h.) |
C |
Relative permittivity |
100 Hz |
- |
IEC 60250 |
3.1 |
C |
Relative permittivity |
1 MHz |
- |
IEC 60250 |
3.0 |
C |
Dissipation factor |
100 Hz |
10-4 |
IEC 60250 |
5 |
C |
Dissipation factor |
1 MHz |
10-4 |
IEC 60250 |
90 |
C |
Volume resistivity |
|
Ohm·m |
IEC 60093 |
1E14 |
C |
Surface resistivity |
|
Ohm |
IEC 60093 |
1E16 |
C |
Electric strength |
1 mm |
kV/mm |
IEC 60243-1 |
33 |
C |
Comparative tracking
index CTI |
Solution A |
Rating |
IEC 60112 |
275 |
|
Comparative tracking
index CTI M |
Solution B |
Rating |
IEC 60112 |
125 |
|
Electrolytic corrosion |
|
Rating |
IEC 60426 |
A1 |
Other properties
(23 °C) |
C |
Water absorption
(Saturation value) |
Water at 23 °C |
% |
ISO 62 |
0.30 |
C |
Water absorption
(Equilibrium value) |
23 °C; 50 % RH |
% |
ISO 62 |
0.12 |
C |
Density |
|
kg/m³ |
ISO 1183 |
1200 |
|
Water permeation |
23 °C; 85 % RH; 100 µm
film |
g/(m²·24 h) |
ISO 15106-1 |
15 |
|
Gas permeation |
Oxygen; 100 µm film |
cm³/(m²·24 h*bar) |
acc. ISO 2556 |
700 |
|
Gas permeation |
Oxygen; 25.4 µm (1 mil)
film |
cm³/(m²·24 h*bar) |
acc. ISO 2556 |
2760 |
|
Gas permeation |
Nitrogen; 100 µm film |
cm³/(m²·24 h*bar) |
acc. ISO 2556 |
130 |
|
Gas permeation |
Nitrogen; 25.4 µm (1 mil)
film |
cm³/(m²·24 h*bar) |
acc. ISO 2556 |
510 |
|
Gas permeation |
Carbon dioxide; 100 µm
film |
cm³/(m²·24 h*bar) |
acc. ISO 2556 |
4300 |
|
Gas permeation |
Carbon dioxide; 25.4 µm
(1 mil) film |
cm³/(m²·24 h*bar) |
acc. ISO 2556 |
16900 |
|
Bulk density |
Pellets |
kg/m³ |
ISO 60 |
660 |
Material
specific properties |
C |
Viscosity number |
|
cm³/g |
ISO 1628-4 |
59 |
|
Refractive index |
Procedure A |
- |
ISO 489 |
1.586 |
|
Haze for transparent
materials |
3 mm |
% |
ISO 14782 |
< 0.8 |
|
Luminous transmittance
(clear transparent materials) |
1 mm |
% |
ISO 13468-2 |
89 |
C |
Luminous transmittance
(clear transparent materials) |
2 mm |
% |
ISO 13468-2 |
89 |
|
Luminous transmittance
(clear transparent materials) |
3 mm |
% |
ISO 13468-2 |
88 |
|
Luminous transmittance
(clear transparent materials) |
4 mm |
% |
ISO 13468-2 |
87 |
Processing
conditions for test specimens |
C |
Injection molding-Melt
temperature |
|
°C |
ISO 294 |
300 |
C |
Injection molding-Mold
temperature |
|
°C |
ISO 294 |
80 |
C |
Injection
molding-Injection velocity |
|
mm/s |
ISO 294 |
200 |